LWIR Continuous Zoom Lens 30-150mm f/0.85-1.2
LWIR Continuous Zoom Lens 30-150mm f/0.85-1.2
Model
GCZ53012D

Item specifics

LWIR Lens
30-150mm f/0.85-1.2
Applications
Security and Surveillance
Focus Mechanism
Motorized

Review

Description

  • Specifications
  • Download file
  • FAQ
  • Video
  • Applications
Specifications
HFOV
160x120
320x240
336x256
384x288
640x480
640x512
1024x768
1280x1024
25μm
1.5°-7.6°
3.1°-15.2°
3.2°-15.9°
3.7°-18.2°
/
/
/
/
17μm
1°-5.2°
2.1°-10.4°
2.2°-10.9°
2.5°-12.4°
4.2°-20.6°
4.2°-20.6°
/
/
12μm
0.7°-3.7°
1.5°-7.3°
1.5°-7.7°
1.8°-8.8°
2.9°-14.6°
2.9°-14.6°
/
/

Optical

Focal Length[mm]
30-150
F/#
0.85-1.2
Average Transmission
≥84%

Foucs Range

5m-Infinity

Wavelength
8-12μm

Mechanical

Interface
Flange
Focus Mechanism
Motorized
Dimensions [mm]
Ø148x236(Front flange Φ172 )
Weight
<2.9kg

Electrical & Communications

Power Input

DC 6-12V 

Communications 

Optional

Environmental

Operating Temperature
-40℃ to +85
Storage Temperature
-60℃ to +85
External Coating
DLC
Front Element Sealing
IP67
Download document
FAQ
- Why is the lens autofocus not clear?

There are many reasons why the lens autofocus is not clear; the main reasons are as follows which can be checked one by one:

1. During the focusing process, if there is a large moving target in the lens screen (occupying more than 1/3 of the picture), just refocus;

2. If the lens is used for a long time, and the gear, CAM and other transmission parts wear and tear, resulting in unclear focus, adjust the module or control board parameters to make the focus clear again;

3. For hardware problems such as the potentiometer not working, replace the hardware that does not work.

- Why cannot the lens control board or module connect to the computer?

There are many reasons why the lens control board and the computer cannot be connected; the main reasons are as follows which can be checked one by one:

1. Replace the USB port, which may be incompatible with the data cable;

2. Replace the data cable, which may be incompatible with the computer or of the wrong type;

3. Check if the wiring of the module or the control board is loose;

4. For module or control board hardware problems, replace the hardware.

VIDEO
APPLICATIONS
Homeland Security
Maritime & Naval
Security & Surveillance