LWIR Infrared Thermal Camera Module丨640*512 17μm
LWIR Infrared Thermal Camera Module丨640*512 17μm
LWIR Infrared Thermal Camera Module丨640*512 17μm
LWIR Infrared Thermal Camera Module丨640*512 17μm
LWIR Infrared Thermal Camera Module丨640*512 17μm
Model
TED6417

Item specifics

Detector Type
Uncooled focal plane
Pixel Pitch
17μm x 17μm
Resolution
640x512
Size
41x41x47.6mm/28x28x35mm
Analog video output
CVBS
Digital video output
BT656/SDI

Review

Description

  • Specifications
  • Download file
  • FAQ
  • Video
  • Applications
Specifications

Detector characteristic

Detector type
Uncooled focal plane
Resolution
640*512
Pixel Pitch
17μm
Wavelength
8-14μm
Frame Rate
25Hz/30Hz/50Hz/60Hz
NETD
40mk/50mk(F/1,300K,30hZ)
Thermal time constant
<10ms

Image adjustment

Polarity display
White/Black Hot
Pseudo Colour 
Support 6 pseudo colors
Cross display
On/Off
Cross position
Adjustable
Image gain
Adjustable
Image brightness
Adjustable
Image enhancement
Adjustable
Image rollover
Veryical/Level
Electronic zoom
1-10 times
Background correction
Support
Automatic focus
Support

Interface

Digital Video Output 
BT656/SDI
Analogue Video Output 
CVBS
Communication Interface
RS232/RS422/TTL/RS485
DC motor
Support 2 sets
Stepper motor iinterface
Customized

System characteristic

Operating Voltage
DC 12V
Power Consumption
≤1.5W
Image stabilization time
<6s
Defensive funcation
Inversed grafting

Pysical characteristic

The host size
41mm*41mm*47.6mm(28mm*28mm*35mm)
The host weight
65g/≤45g

Environmental adaptation

Operating Temperature
-40℃~+60℃(can be extended from -40℃~+70)
Storage Temperature
-45℃~+85
Download document
file name
type
download
LWIR Infrared Thermal Camera Module丨TED6417 640*512 17μm
PDF
FAQ
- Why the lens autofocus is not clear?

There are many reasons why the lens autofocus is not clear, the main reasons are as follows which can be checked one by one:

1. During the focusing process, there is a large moving target in the lens screen (occupying more than 1/3 of the picture), which can be refocused;

2. If the lens is used for a long time, the gear, CAM and other transmission parts wear and tear, resulting in unclear focus, the module or control board parameters can be adjusted to make the focus clear again;

3. Hardware problems, such as the potentiometer does not work, replace the hardware that does not work.

- Why cannot the lens control board or module connect to the computer?

There are many reasons why the lens control board and the computer cannot be connected, the main reasons are as follows which can be checked one by one:

1. Replace the USB port, which may be incompatible with the data cable;

2. Replace the data cable, maybe the data cable is not compatible with the computer or the cable data is wrongly selected;

3. Confirm the wiring of the module or the control board, maybe the wiring is loose;

4. Module or control board hardware problem, replace the hardware.